FC-51 1.5KW 1PHAS 220VAC
Specifications :
Input voltage: 3 phase, 380 - 480 VAC
Output voltage: 3 phase, 380 - 480 VAC
Output frequency: 0 to 400 Hz
Applied motor output: 1,5 kW / 2 HP
Ambient temperature: Maximum of +50C
Overall width: 150mm
Overall length: 70mm
Overall depth: 148mm
Control Panel: Yes
Drive Type: Variable Speed
Field Bus Communication Type: Modbus
Filter Included: Yes
Function: Motor Control
IP Rating: IP20
Mounting Type: Panel Mount
Standards Met: ISO 14001, RoHS, WEEE
FR-D720S-0.75K
Specifications :
Applicable motor capacity (kW) 0.75
Rated capacity(kVA) 1.7
Rated current(A) 4.2
Overload current rating 3
Voltage Three-phase 200 to 240V
Rated input AC voltage/frequency
Single-phase 200 to 240V 50Hz/60Hz
Pemnissible AC voltage fluctuation
170 to 264V 50Hz/60Hz
Permissible frequency fluctuation 5%
Power supply capacity (kVA) 2.3
Protective structure(JEM1030)
Enclosed type (IP20).
Cooling system
Self-cooling
Forced air cooling
FR-CS84-120-60
Specifications :
Input 18.5A 3PH AC380-480V 50/60Hz
Output 12.0A 3PH AC380-480Vmax 0.2-400Hz
Manual book include
ATV310HU15N4E 3P 380V 1.5KW
Specifications :
Motor power kW: 1.5 kW
Motor power hp: 2 hp
Noise Level: 50db
Supply frequency: 50/60 Hz +/- 5 %
Communication port protocol: Modbus
Connector type: RJ45 for Modbus on front face
Physical interface: 2-wire RS 485 for Modbus
Transmission frame: RTU for Modbus
Line current: 5.4A
Apparent power 4.3 kVA
Prospective line Isc <= 5 kA
Continuous output current 4.1 A at 4 kHz
Maximum transient current 6.2 A for 60 s
Power dissipation in W 51.82 W at In
Speed drive output frequency 0.5…400 Hz
Nominal switching frequency 4 kHz
Switching frequency 2…12 kHz (adjustable)
Dimension: 151 mm (H) x 105 mm (W) x 143mm (D)
ATV310H075N4E 3P 0.75KW 1HP
Specifications :
Product destination: Asynchronous motors
Quantity per set: Set of 1
EMC filter: Without EMC filter
Supply frequency: 50/60 Hz +/- 5 %
Communication port protocol: Modbus
Connector type: RJ45 (on front face) for Modbus
Physical interface: 2-wire RS 485 for Modbus
Transmission frame: RTU for Modbus
Transmission rate:
4800 bit/s
9600 bit/s
19200 bit/s
38400 bit/s
Number of addresses: 1…247 for Modbus
Communication service :
Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)